# Troubleshooting

This section addresses common issues that may occur during Intel® VROC setup, RAID configuration, or runtime operation on Linux\*. Each issue includes likely causes and corresponding solutions to help you quickly restore system functionality.

### **Issue:** RAID volumes do not appear after reboot

* **Possible Cause 1:** The configuration file `/etc/mdadm.conf` is missing or incomplete.
  * **Solution:** Rebuild the configuration file and rescan all arrays:

```
mdadm --examine --scan > /etc/mdadm.conf
mdadm --assemble --scan
```

* **Possible Cause 2:** The mdadm service is not enabled at startup.
  * **Solution:** Enable the service to ensure automatic RAID assembly on boot:

```
# systemctl enable mdmonitor.service
# systemctl start mdmonitor.service
```

### **Issue:** RAID creation fails or member disks are not detected

* **Possible Cause 1:** Intel VMD driver is not loaded or initialized.
  * **Solution:** Verify the VMD module is active and visible to the system:

```
# lspci | grep -i vmd
# ls /sys/class/vmd/
```

If missing, load the driver manually:

```
# modprobe vmd
```

* **Possible Cause 2:** NVMe devices are not properly enumerated under Intel® VROC control.
  * **Solution:** Confirm that BIOS VMD configuration is enabled for the corresponding PCIe ports.

{% hint style="info" %}
**Pro Tip:** Reboot into BIOS → Advanced → Intel VMD Technology → Enable all NVMe ports under VROC control.
{% endhint %}

### **Issue:** RAID volume rebuild speed is extremely slow

* **Possible Cause:** The default synchronization speed is limited to 200MB/s.
  * **Solution:** Increase the resync speed limit for NVMe-based arrays:

```
# cat /sys/block/md0/md/sync_speed_max
# echo 5000000 > /sys/block/md0/md/sync_speed_max
```

### **Issue:** LED indicators are not functioning or show incorrect states

* **Possible Cause:** The ledmon daemon is not running.
  * **Solution:** Download the correct storage driver from the server manufacturer's support website. During the OS installation (this is common in Windows Server), look for an option to **Load driver**. Provide the driver files via a separate USB drive or another virtual media slot to allow the installer to detect the drives. For Linux, you may need a more recent kernel version or a specific distribution that includes the required driver.

### **Issue: Installation fails midway with an error**

* **Possible Cause 1:** Corrupted installation media.
  * **Solution:** Restart and verify the LED monitoring service:

```
# systemctl restart ledmon.service
# systemctl status ledmon.service
```

* **Possible Cause 2:** The server’s backplane is not supported for LED control.
  * **Solution:** Intel® VROC LED Management supports only NVMe drives connected via compatible backplanes (SGPIO/SES-2). Drives attached directly to the motherboard (M.2) or through PCIe adapters are not LED-controllable.

### **Issue:** RAID migration or Online Capacity Expansion (OCE) fails

* **Possible Cause1:** Insufficient spare drives or available capacity.
  * **Solution:** Verify that the target RAID level’s minimum drive count is satisfied and that sufficient unallocated space exists on each member disk.
* **Possible Cause2:** Bitmap or PPL feature is still enabled.
  * **Solution:** Disable bitmap or PPL before executing OCE or RAID migration:

```
# mdadm --grow --consistency-policy=resync /dev/md/volume
```

### **Issue:** mdadm monitoring alerts are not triggered

* **Possible Cause:** Missing or misconfigured email address in `/etc/mdadm.conf`.
  * **Solution:** Add the following line to enable email-based alerts and restart mdmonitor:

```
# systemctl restart mdmonitor.service
```

### **Issue:** mdadm reports “device busy” or cannot stop an array

* **Possible Cause:** The RAID volume is still mounted or in use by another process.
  * **Solution:** Unmount the filesystem and reattempt stopping the array:

```
# umount /mnt/data
# mdadm --stop /dev/md/volume
```

If needed, check open file handles:

```
# lsof | grep /dev/md/volume
```

### **Issue:** RAID volume appears degraded after unexpected power loss

* **Possible Cause:** Incomplete write operation or missing parity sync.
  * **Solution:** Check the array status and trigger manual resync if necessary:

```
# cat /proc/mdstat
# mdadm --detail /dev/md/volume
# mdadm --assemble --scan
```

### **Issue:** RAID volume not found in Linux installer

* **Possible Cause:** The installation kernel lacks the Intel VROC driver.&#x20;
  * **Solution:**&#x20;
    * Use a Linux distribution with Intel VROC inbox support.
    * If not available, load Intel’s out-of-box driver package during OS installation.
    * Reboot and confirm that the array is recognized via `lsblk` or `mdadm --detail`.

{% hint style="info" %}
***Final Tip:*** Always maintain an up-to-date backup of `/etc/mdadm.conf` and RAID metadata before performing reshape, resize, or migration operations.
{% endhint %}


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://doc.engenius.ai/intel-r-vroc-for-linux-guide/appendix/troubleshooting.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.