> For the complete documentation index, see [llms.txt](https://doc.engenius.ai/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://doc.engenius.ai/intel-r-vroc-for-windows-guide/vroc-configuration/using-the-intel-r-vroc-gui.md).

# Using the Intel® VROC GUI

**In this chapter, you will learn:**

* How to install the Intel® VROC Graphical User Interface (GUI).
* How to navigate all the main pages and functions of the GUI.
* How to create different types of RAID volumes, including Matrix RAID.
* The correct procedure for safely deleting a RAID volume.

This chapter provides a comprehensive guide to the Intel® VROC Graphical User Interface (GUI). It covers installation, an overview of all interface components, and step-by-step instructions for creating and deleting RAID volumes within the Windows operating system.

### Installing the Intel® VROC GUI

This section outlines the installation process for the Intel® VROC product family, enabling fully integrated management of storage devices within a Windows environment.

{% hint style="info" %}
If the system lacks an active network connection, the installer cannot automatically download required components. In that case, manually install Microsoft Windows Desktop Runtime – 6.0.3 (x64) and Microsoft Visual C++ 2015–2019 Redistributable – 14.24.28127.4 (x64) before proceeding. Without these, the Intel® VROC GUI will not function properly.
{% endhint %}

#### Prerequisites for VROC GUI

Beginning with Intel® VROC version 8.0, the GUI requires the following packages. If the installer detects an active network connection, it will attempt to download and install them automatically.

1. Microsoft Windows Desktop Runtime
2. Microsoft Visual C++ Redistributable

#### Installation Steps

1. Right-click `SetupVROC.exe` and select **Run as administrator**.<br>

   <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FqEIxpU8E5qVnnI0fH1Rl%2Fimage.png?alt=media&amp;token=2128e36b-0c5d-4296-96d2-0355a21d559e" alt=""><figcaption></figcaption></figure>
2. On the Welcome screen, click **Install**.

   <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2Fhagytg75McatBVgG3SOW%2Fimage.png?alt=media&amp;token=32e3d507-2f7a-4a3e-a680-252424d2f8c2" alt=""><figcaption></figcaption></figure>
3. Review the **Warning** screen and click **Next**.
4. Read and **Accept** the End User License Agreement (EULA).
5. Confirm the **Destination Folder** or change it, then click **Next**.
6. On the **Confirmation** screen, click **Install** to begin the installation.

   <br>

   <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FsxuHMMM0WTa6CAwMLvwq%2Fimage.png?alt=media&amp;token=aa880ce7-5ddc-4b4d-9634-ab330e9727ed" alt=""><figcaption></figcaption></figure>
7. After the installation is complete, you must restart your computer. Select **Restart Now** to finalize the process.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FVMHad4UOGtyx7jkTBqil%2Fimage.png?alt=media&amp;token=7c18a121-09e2-4b84-a925-28ed0be606e4" alt=""><figcaption></figcaption></figure>

### Navigating the GUI

To launch the application, open the Windows Start menu, find **Intel® Virtual RAID on CPU**, and select **Run as administrator**.

The installed Intel® VROC Upgrade Key determines available RAID features. For example, a Premium Upgrade Key unlocks all RAID levels, while Standard or Intel® SSD-only keys enable a subset of features.

#### Home Page

The home page provides an at-a-glance view of your storage system's health and configuration.

* **Navigation:** Use the back and forward arrows in the top-left corner of the window to navigate between previously viewed pages. A breadcrumb path also appears when opening Controller, Array, or Volume pages, enabling direct navigation.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FWOguIifQznf9LRfSQWuu%2Fimage.png?alt=media&amp;token=889fccb4-3922-4384-a937-92503eaaaafc" alt=""><figcaption></figcaption></figure>

* **Status Bar**: Displays the overall health of the system (e.g., "Your system is functioning normally," or warnings/errors).
* **Summary Pane**: Lists all detected RAID controllers (e.g., Intel VROC Premium). Clicking a controller navigates to its detailed properties page.
* **Side Menu**: Provides navigation to all other pages within the application, such as Drives, Create Volume, Notifications, etc.

#### Other GUI Pages

* **Drives Page**: Lists all physical drives detected on the platform, with options to filter, search, and perform actions like activating LEDs or ejecting a drive.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FyySOXtkuj2KZTrZ8mwNV%2Fimage.png?alt=media&amp;token=228cc699-51c0-4766-9c32-2d24a3f5088e" alt="" width="563"><figcaption></figcaption></figure>

* **Create Volume Page**: The starting point for creating new RAID volumes.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FaUrXv2HiLFMN5T0IYJuc%2Fimage.png?alt=media&amp;token=40fb5066-77bf-4a88-8edd-dfbf97d08cb0" alt=""><figcaption></figcaption></figure>

* **Notifications Page**: Logs all system events, including errors, warnings, and informational messages.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FRN9nzDZE3tM8RMIQOBNC%2Fimage.png?alt=media&amp;token=4b229e70-bd5e-40f8-9a56-c9060fd8567a" alt=""><figcaption></figcaption></figure>

* **Preferences Page**: Allows you to configure notification settings.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FiVoiiM59V07Tqn5RcUvM%2Fimage.png?alt=media&amp;token=0fe47597-e8b8-43e3-8aee-460833ae8899" alt=""><figcaption></figcaption></figure>

* **Scheduler Page**: Allows you to schedule automatic verify and repair operations for data consistency.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2Fhiz2mfSwjpvluxvHsFqL%2Fimage.png?alt=media&amp;token=cf915e72-a6e1-46f0-9f03-ff37080f0629" alt=""><figcaption></figcaption></figure>

* **System Report Page**: Displays detailed information about the system hardware, software, and storage configuration.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FfhRguZz2auNx6XNcRFvy%2Fimage.png?alt=media&amp;token=eba4c0d8-67d0-490c-8ec0-0bf5652d05b6" alt=""><figcaption></figcaption></figure>

* **About Page**: Provides application and license information.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FAUxH1HoYeccPH9ERWS4z%2Fimage.png?alt=media&amp;token=665578f9-4267-4685-bf9b-5f20730bca4f" alt="" width="563"><figcaption></figcaption></figure>

* **Help Page**: Contains integrated help documentation.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FiLlIioPwJnE3CBgde8xV%2Fimage.png?alt=media&amp;token=46de9569-3209-4413-9adf-d93fce12db65" alt="" width="563"><figcaption></figcaption></figure>

* **Drive Management:** From the Drives page, you can activate LEDs to identify physical drives, eject selected drives (VMD only), or export drive data to a CSV file.
* **Customization:** Right-click within the drive table to select which data fields are displayed. These preferences are saved and persist across application sessions.

{% hint style="info" %}
**Compatibility Note:** Intel® VROC GUI requires Windows\* 10 RS5 or later, or Windows\* Server 2019 and newer. Ensure the latest Windows updates are installed before launching the GUI.
{% endhint %}

### Creating RAID Volumes

The following section provides step-by-step guidance on using the Intel® VROC GUI to create RAID volumes within a Windows environment.\
\
In this example, the system is assumed to have all required Intel® VROC drivers installed, allowing the operating system to properly recognize the NVMe drives intended for data volume configuration.

Because the creation workflow is nearly identical across different RAID levels, only one representative example is demonstrated in this chapter. Minor variations may apply depending on the selected RAID level and the number of participating drives.

#### Creating a 2-Drive RAID 0 Data Volume

#### **“Create Volume” Page**

The following example illustrates how to create a **two-drive RAID 0 data volume** using the Intel® VROC GUI.

* In the left-hand navigation pane, click the **“+ (Create Volume)”** icon to start the volume creation process.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FMTthwCGRT5a0ASspXuFM%2Fimage.png?alt=media&amp;token=39f06e28-f311-4538-85f5-c29dcd46629f" alt=""><figcaption></figcaption></figure>

#### **Selecting the Controller**

1. Select the **NVMe Devices** controller if it is not already selected.
2. From the available RAID configuration options, choose **Optimized Disk Performance (RAID 0)** to create a striped array.
3. Once the selection is complete, click **Next** to proceed.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2F3BiMl4WU5NyijJisZEpe%2Fimage.png?alt=media&amp;token=eefd165a-a1af-46e5-a735-549b079529df" alt=""><figcaption></figcaption></figure>

#### **Configure Volume**

Follow the steps below to configure the new RAID volume.

{% stepper %}
{% step %}
**Select the two drives to be included in the new volume.**

* When prompted to add this volume to an existing array, select **No**.
* Choose the two remaining available drives for the new data volume.

If the selected drives reside under different **Volume Management Domains (VMDs)** or CPUs, enable **VMD Controller Spanning** to include drives across domains.

{% hint style="info" %}
**Note:** VMD Controller Spanning is supported **only for data volumes** and is **not available for boot volumes.**
{% endhint %}
{% endstep %}

{% step %}
**Click&#x20;**<mark style="color:purple;">**Next**</mark>**&#x20;to continue.**

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FEhXGWSovmO7qjlhZqJBH%2Fimage.png?alt=media&amp;token=a71ed033-2fef-45d9-a9f4-62a9ab875144" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Configure the volume parameters.**

Specify a **Name** for the volume, or keep the default value (**Volume\_0000**).\
For this example, all other parameters are left at their default settings. Click **Next** to proceed.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FufAr9rcVfDVVT1a4qInb%2Fimage.png?alt=media&amp;token=0827c5d0-42ef-445e-bb15-3226f44473a6" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Click&#x20;**<mark style="color:purple;">**Create Volume**</mark>**&#x20;to start the volume creation process.**

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FGiViAnQfFWrp0EDJeWkY%2Fimage.png?alt=media&amp;token=f62dcf67-4bf2-45ce-98df-704341e49568" alt=""><figcaption></figcaption></figure>
{% endstep %}

{% step %}
**Click&#x20;**<mark style="color:purple;">**OK**</mark>**&#x20;when prompted to confirm.**

The new RAID 0 data volume is now created successfully.

<figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FoPafo9I2o42z7ct7WGJS%2Fimage.png?alt=media&amp;token=a0e49bf7-b33a-4a8e-a81f-a160c339b06e" alt=""><figcaption></figcaption></figure>

{% endstep %}
{% endstepper %}

#### View Volume Properties

1. After the RAID volume (**Volume\_0000**) is created, the **Properties** pane automatically refreshes to display the current **status**, **configuration details**, and **available management options** for the new RAID volume.

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FuN6feJfwfNL1F7gbfdda%2Fimage.png?alt=media&amp;token=78ed9db7-a983-48e3-94c9-de17dda5e4c0" alt="" width="505"><figcaption></figcaption></figure></div>

2. A corresponding event is logged in the **Notifications** page.\
   Before the new volume can be used, it must still be **formatted and mounted** within the Windows\* environment, just like any newly added drive.

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2Fx2J1sDRgZIw2PE8hHxWj%2Fimage.png?alt=media&amp;token=8c2f69d2-d847-4d3c-922f-2f3ed851d23f" alt="" width="563"><figcaption></figcaption></figure></div>

#### Creating a 3-Drive RAID 5 Data Volume

#### “Create Volume” for RAID 5

The following example demonstrates how to create a **three-drive RAID 5 data volume** using the Intel® VROC GUI.

1. Click **Create Volume** to begin the configuration process.
2. Select the **NVMe Devices** controller if it is not already selected.\
   From the list of available RAID configuration types, choose **Efficient Data Hosting and Protection (RAID 5)**.\
   Click **Next** to continue.
3. Select **three available drives** to include in the new volume.\
   On this platform, each **Intel® VMD controller** provides two direct NVMe connections, which requires the volume to span across multiple controllers.

When spanning is enabled, the following warning message appears:

{% hint style="danger" %}
WARNING: RAID volume spanned across Intel® VMD controllers cannot be used as a bootable volume.
{% endhint %}

To proceed, check the box **Enable Intel® VMD Controller Spanning**.\
This option must be selected before drives from multiple controllers can be added to the array. Once the selection is complete, click **Next** to continue.

{% hint style="info" %}
**Note:** a warning may appear if one selected drive differs in size by more than 10%, meaning the larger drive will have unused capacity. To avoid wasted space, use drives of equal capacity when creating arrays. Spanning across Intel® VMD domains is optional but available for configuration flexibility.
{% endhint %}

#### “Available Drives” for RAID 5

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FTAQO8UH3LcFIQ7iSWYlA%2Fimage.png?alt=media&amp;token=4425e41f-09a5-46f6-9b52-bd9c458463c1" alt="" width="563"><figcaption></figcaption></figure></div>

#### “Configure Volume Name and Size” for RAID 5

1. Specify a **Name** for the new RAID 5 volume.\
   In this example, the default name (**Volume\_0001**) is used.
2. For RAID 5 volumes, you can enable **RAID Write Hole Closure**, a feature designed to maintain data integrity during unexpected power loss.\
   It is strongly recommended to enable this feature **during volume creation**—changing its state after data has been written may put existing data at risk.\
   When enabled, you can assign an unused drive as an additional member and choose either **Distributed** or **Journaling** mode in the *Advanced* pane.<br>

   <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FQt0kmNAOeoqoxUbJEnwP%2Fimage.png?alt=media&amp;token=716c2def-c806-4fd8-80b7-479a93afbb0c" alt=""><figcaption></figcaption></figure>
3. Click **Create Volume** to begin the process.<br>

   <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FfPnGrYIzLUsvSCNX4bOJ%2Fimage.png?alt=media&amp;token=1e59b9bc-50ae-4d0f-a102-253951251559" alt=""><figcaption></figcaption></figure>
4. Click **OK** to confirm and complete the creation.
5. After confirmation, the landing page will display the newly created volume.\
   All volume properties and configuration details can be reviewed here.

### View RAID 5 Volume Properties

#### Creating a Matrix RAID

The following example demonstrates how to create **two RAID volumes (RAID 0 and RAID 1)** on a single array using the Intel® VROC GUI.

1. Follow the same procedure described in **Section 7.1** to create a **two-drive RAID 0** volume.\
   It is recommended **not to allocate all available disk space** for the first volume, leaving sufficient capacity for creating the second volume on the same array.
2. Once the first volume is created, the Intel® VROC GUI will display it in the **Configured Storage** section.\
   To create the second volume, click **Create Volume** and continue the configuration process.

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FYwPlSi4qpbIxxOZdLro7%2Fimage.png?alt=media&amp;token=da3a7b1a-5783-43eb-a55e-8586745a60a2" alt="" width="563"><figcaption></figcaption></figure></div>

#### Configuring Matrix Volume Name

1. Specify a **Name** for the new volume, or keep the default value (**Volume\_0001**).\
   Click **Next** to continue.<br>

   <div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FM4vUTfToDDwM6IGjv6iu%2Fimage.png?alt=media&amp;token=96bb8b8c-0026-4ab2-9716-ffdb36068211" alt=""><figcaption></figcaption></figure></div>
2. Click **Create Volume** to begin the volume creation process.<br>

   <div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2F80K5X4BgPG8MaNDNIQM8%2Fimage.png?alt=media&amp;token=66b7442f-0774-45ad-bb51-4201a3b1bb2f" alt=""><figcaption></figcaption></figure></div>
3. Click **OK** to confirm and complete the configuration.

#### **Viewing the Created Matrix Volumes**

* In the **Controller Properties** page, both the newly created **Array** and its associated **RAID volumes** (**Volume\_0000** and **Volume\_0001**) will be displayed.\
  Clicking either volume name opens its corresponding **Properties** page for detailed configuration and status information.<br>

  <figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FAPUZSsytUHKb7JyZbhYY%2Fimage.png?alt=media&amp;token=c20f8481-d809-4991-a208-81521d6d7062" alt=""><figcaption></figcaption></figure>

### Viewing RAID Volumes in Windows Control Panel Applets\*

This section shows how newly created RAID volumes appear in *Windows Device Manager*\* and **Disk Management**.

#### RAID Volumes in Device Manager

After a RAID volume is created, open **Device Manager**. The new volume appears under **Disk drives**, confirming that Windows has recognized the Intel® VROC RAID array.<br>

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FN8hvyEch1yXxiplFrCU5%2FGroup%20230%2C%20%E7%BE%A4%E7%B5%84%E7%89%A9%E4%BB%B6?alt=media&amp;token=13f2f2ce-8598-4b27-8a7a-7a21bae0f3cb" alt=""><figcaption></figcaption></figure></div>

### Disk Management Page

* Open **Disk Management**. The newly created RAID volume will be listed as available for formatting and partitioning. Any attached non-RAID drives will also be displayed here.

{% hint style="info" %}
**Note:** USB thumb drives used as installation media may still appear with assigned drive letters in this view.
{% endhint %}

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FMbN7i3FOXI9WxBumIMj8%2FGroup%20233%2C%20%E7%BE%A4%E7%B5%84%E7%89%A9%E4%BB%B6?alt=media&amp;token=9e2be64f-fe7d-46ad-8e3e-4fc9a529d6f6" alt=""><figcaption></figcaption></figure></div>

### Deleting a RAID Volume

Follow the steps below to delete an existing RAID volume using the Intel® VROC GUI.\
From the **Home** page, select the RAID volume you want to remove.<br>

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2F6vAuNpfeNpSG7Vk2wzpB%2Fimage.png?alt=media&amp;token=f7d433aa-3729-4ec5-a0ed-58148ff25ded" alt=""><figcaption></figcaption></figure></div>

1. Under **Volume Management**, open the **Actions** menu.

{% hint style="info" %}
**Note:** The **Delete Volume** option is available only when a volume is selected.\
Exercise caution—once a volume is deleted, **all data on the array will be permanently lost and cannot be recovered.**
{% endhint %}

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2F1dhExc6679EngXqzKRZ5%2Fimage.png?alt=media&amp;token=fe2db2df-e5de-41ad-a6cc-680d311cfbc9" alt=""><figcaption></figcaption></figure></div>

2. When prompted with the warning message, select **Yes** to confirm and complete the deletion process.<br>

<div align="left"><figure><img src="https://2929691634-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FA4uFR7p0ENdspVseA2um%2Fuploads%2FQOGm7RieI7BUgz6UHY5t%2Fimage.png?alt=media&amp;token=d7295a00-e987-4019-b013-48c48800e621" alt=""><figcaption></figcaption></figure></div>


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://doc.engenius.ai/intel-r-vroc-for-windows-guide/vroc-configuration/using-the-intel-r-vroc-gui.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.